Product Features: Measures: Earth and differential leakage currents Leakage currents through the earth (PE) conductor Appliance current consumption without interruptions to the circuit Low influence of external low frequency magnetic fields: @ IN: 3.500 mA – 600.0 mA ≤ 30 A/m, operating class 2 True-RMS measurements for accuracy when measuring complex, non-sinusoidal waveforms Mechanical jaw lock with 1.2 in. (30 mm) opening assures accuracy of low current measurements Highest resolution of 0.001 mA while measuring up to 60 A Broad frequency range 15 Hz to 1 kHz Selectable filters: Low Pass 50/60Hz filter to perform measurements on equipment driven by Variable Frequency Drives (VFDs) or affected by high frequency noise Appliance Filter to conduct leakage current measurements on appliances No filter Selectable limits: 0.25 mA, 0.5 mA, 3.5 mA, 10 mA, 12 mA Max readings and hold function High safety rating: CAT III 600 V Battery-saving design with an auto backlight off and auto power off Applications Trace the source of earth leakage current Identify intermittent GFCI trips without switching equipment off Check a system for an electrical break of insulation where current is flowing to the ground Where industrial leakage current testing is required